KLM Labs

Roof pitch chart: 1/12 to 24/12 in degrees, slope and rafter length

Roof pitch is the rise in inches for every 12 inches of run: a 6/12 roof climbs 6" per foot, which is 26.6° and a 50% slope. The chart gives the angle, slope, rafter cuts and rafter length per foot of run for every pitch from 1/12 to 24/12.

Free to print, no sign-up. US Letter, 1 page, 34 KB. Every number is worked out by Construction Calculator 1.1.1's own formulas.

Page 1 of the printable roof pitch chart, 1/12 to 24/12: Angle, slope, cuts and rafter length per foot of run for each pitch, and common rafter lengths by building span.
The printable chart, with the same numbers as the tables on this page. US Letter, 1 page, 34 KB.

Roof pitch to degrees, slope and rafter length, 1/12 to 24/12

PitchAngle (plumb cut)Seat cutSlopeRafter per foot of runMultiplier
1/124.8°85.2°8.3%≈ 12-1/16"1.0035
2/129.5°80.5°16.7%≈ 12-3/16"1.0138
3/1214°76°25%≈ 12-3/8"1.0308
4/1218.4°71.6°33.3%≈ 12-5/8"1.0541
5/1222.6°67.4°41.7%13"1.0833
6/1226.6°63.4°50%≈ 13-7/16"1.118
7/1230.3°59.7°58.3%≈ 13-7/8"1.1577
8/1233.7°56.3°66.7%≈ 14-7/16"1.2019
9/1236.9°53.1°75%15"1.25
10/1239.8°50.2°83.3%≈ 15-5/8"1.3017
11/1242.5°47.5°91.7%≈ 16-1/4"1.3566
12/1245°45°100%≈ 17"1.4142
13/1247.3°42.7°108.3%≈ 17-11/16"1.4743
14/1249.4°40.6°116.7%≈ 18-7/16"1.5366
15/1251.3°38.7°125%≈ 19-3/16"1.6008
16/1253.1°36.9°133.3%20"1.6667
17/1254.8°35.2°141.7%≈ 20-13/16"1.7341
18/1256.3°33.7°150%≈ 21-5/8"1.8028
19/1257.7°32.3°158.3%≈ 22-1/2"1.8727
20/1259°31°166.7%≈ 23-5/16"1.9437
21/1260.3°29.7°175%≈ 24-3/16"2.0156
22/1261.4°28.6°183.3%≈ 25-1/16"2.0883
23/1262.4°27.6°191.7%≈ 25-15/16"2.1619
24/1263.4°26.6°200%≈ 26-13/16"2.2361
Angle = arctan(pitch ÷ 12), the roof’s angle and the rafter’s plumb cut; seat cut = 90° − the plumb cut. Slope = pitch ÷ 12 as a percent. Rafter per foot of run = √(12² + pitch²) inches, to the nearest 1/16" (≈ when rounded); the multiplier is the same length in feet, to 4 places. Rafter lengths are line lengths with no overhang.

Common rafter length by building span and pitch (line length, no overhang)

Building span4/126/128/1210/1212/12
12 ft≈ 6' 3-7/8"≈ 6' 8-1/2"≈ 7' 2-9/16"≈ 7' 9-3/4"≈ 8' 5-13/16"
16 ft≈ 8' 5-3/16"≈ 8' 11-5/16"≈ 9' 7-3/8"≈ 10' 4-15/16"≈ 11' 3-3/4"
20 ft≈ 10' 6-1/2"≈ 11' 2-3/16"≈ 12' 0-1/4"≈ 13' 0-3/16"≈ 14' 1-11/16"
24 ft≈ 12' 7-13/16"≈ 13' 5"≈ 14' 5-1/16"≈ 15' 7-7/16"≈ 16' 11-5/8"
28 ft≈ 14' 9-1/16"≈ 15' 7-13/16"≈ 16' 9-15/16"≈ 18' 2-11/16"≈ 19' 9-9/16"
32 ft≈ 16' 10-3/8"≈ 17' 10-11/16"≈ 19' 2-3/4"≈ 20' 9-15/16"≈ 22' 7-1/2"
The run is half the span. Length = run × √(144 + pitch²) ÷ 12, from the outside of one wall’s top plate to the ridge line, before any ridge-board deduction or overhang, to the nearest 1/16".

What is a 4:12 roof pitch?

A 4/12 (or 4:12) roof rises 4" for every 12" of run: an angle of 18.4° and a 33.3% slope. Each foot of run takes about 12-5/8" of rafter, a multiplier of 1.0541. For asphalt shingles, the 2021 International Residential Code requires double underlayment on slopes from 2/12 up to 4/12 (R905.2.2).

What is a 6/12 roof pitch?

A 6/12 roof rises 6" per foot of run: 26.6°, a 50% slope. The rafter is about 13-7/16" long for each foot of run, a multiplier of 1.118, and its plumb cut is 26.6° with a 63.4° seat cut.

What’s a normal pitch for a roof?

There is no single normal pitch; it is a design choice. What the code sets is the lowest slope each roof covering may go on. The 2021 IRC minimums:

Roof covering Lowest slope, 2021 IRC
Mineral-surfaced roll roofing 1/12 (R905.5.2)
Asphalt shingles 2/12, with double underlayment from 2/12 up to 4/12 (R905.2.2)
Clay and concrete tile 2-1/2/12, with double underlayment from 2-1/2/12 up to 4/12 (R905.3.2)
Metal roof shingles 3/12 (R905.4.2)
Wood shingles 3/12 (R905.7.2)
Wood shakes 3/12 (R905.8.2)
Slate 4/12 (R905.6.2)

The 2024 IRC keeps these minimums under the same section numbers, and R802.4.1 too. Your city or county may have adopted another edition or amended it, and the covering’s maker can ask for more: check both before you build. The table sums up the model code’s minimums for planning; it is not legal advice.

Roof pitch in degrees, and the multiplier

The angle is arctan(pitch ÷ 12): for 8/12, arctan(0.667) = 33.7°. The multiplier is the rafter length for one foot of run, √(12² + pitch²) ÷ 12, so for 8/12 it is √208 ÷ 12 = 1.2019, about 14-7/16" of rafter per foot. The slope percent is pitch ÷ 12: 8/12 is a 66.7% slope.

How to calculate rafter length

On a gable roof with the ridge in the middle, the run is half the building’s span. Multiply the run by the multiplier: a 24' span at 6/12 is a 12' run, and 12 × 1.118 is 13.42 ft, about 13' 5". That is the line length from the outside of the wall to the ridge line, the center of the ridge board. Each rafter stops at the ridge board’s face, so half the ridge’s thickness comes off it, measured level (square to the plumb cut): for a 1-1/2" ridge, that is 3/4" off the run, about 13/16" along a 6/12 rafter. Any overhang goes on, measured level the same way. The second table gives line lengths for spans of 12' to 32' at five common pitches.

What size rafter to use and how far it may span is a different question, and pitch does not answer it: the IRC sizes rafters from its span tables (R802.4.1), and the American Wood Council publishes span tables for other grades, species and loads.

Plumb and seat cuts

The plumb cut, where the rafter meets the ridge, is at the roof’s angle; the seat cut, where it sits on the wall, is 90° minus that. At 6/12 they are 26.6° and 63.4°; at 12/12 both are 45°.

How the lengths and angles are rounded

Construction Calculator 1.1.1 works rafter lengths from the square root of an exact sum and rounds them to the nearest 1/16", marked ≈ when rounded; angles are rounded to a tenth of a degree. The tables here follow the same steps.

See all 7 construction charts

Sources

  1. International Code Council: 2021 IRC, Chapter 9, Roof Assemblies (R905 minimum slopes; the official text)
  2. UpCodes: 2021 IRC Chapter 9 as adopted without amendments (R905.2.2, R905.3.2, R905.4.2, R905.5.2, R905.6.2, R905.7.2, R905.8.2, read in full)
  3. UpCodes: 2021 IRC Chapter 8, Roof-Ceiling Construction (R802.4.1 rafter size)
  4. Ira S. Griffith, Carpentry, §19 Ridge Piece: a common rafter is shortened by "one-half the thickness of the ridge measured at right angles to the plumb cut"
  5. Mike Sloggatt, Common Rafter Framing, THISisCarpentry (the ridge's full width comes off the building width before it is halved into each rafter's run)
  6. UpCodes: 2024 IRC Chapter 9 as adopted without amendments (Texas Windstorm Insurance Association; R905 minimum slopes)
  7. American Wood Council: Span Tables for Joists and Rafters, 2024 edition